Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Circ J ; 82(7): 1735-1742, 2018 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-29618696

RESUMO

Subclinical leaflet thrombosis (SLT) following transcatheter aortic valve replacement (TAVR) has been increasingly recognized. SLT has the hallmark features of hypo-attenuated leaflet thickening (HALT) on multidetector computed tomography (MDCT), which may result in hypoattenuation affecting motion (HAM). The actual prevalence of this condition is uncertain, with limited observational registries. SLT has caught the attention of the cardiovascular community because of concerns regarding its clinical sequelae, specifically the potential increased incidence of cerebrovascular events. There are available, albeit sparse, data to suggest that when left untreated, SLT may lead to valve deterioration with potential hemodynamic compromise and potentially clinically overt prostheses thrombosis. Some clinicians have opted to treat patients with SLT with anticoagulation. Although anticoagulation may be a rational treatment option, little data exist on the safety and efficacy of this treatment. This is particularly important considering TAVR patients also have higher bleeding risk than the standard population. In this review, we aim to summarize the current evidence on SLT, explore its pathophysiological mechanism, discuss the current treatment options and future trials that may clarify the optimal antithrombotic strategies of SLT.


Assuntos
Tomografia Computadorizada Multidetectores/métodos , Trombose/diagnóstico , Substituição da Valva Aórtica Transcateter/métodos , Anticoagulantes/uso terapêutico , Hemorragia/etiologia , Humanos , Trombose/tratamento farmacológico , Trombose/fisiopatologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
3.
Catheter Cardiovasc Interv ; 91(7): 1365-1370, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29210168

RESUMO

OBJECTIVE: To determine the effect of aorto-ventricular angulation (AA) on procedural success with the Lotus Valve system. BACKGROUND: AA, the angulation of the aortic valve basal plane, may affect the deployment of transcatheter aortic valve replacements (TAVRs). The Lotus Valve system is fully repositionable and delivered on a pre-shaped catheter which may alter the impact of AA on its deployment. The effect of AA on procedural and clinical outcomes with the Lotus valve is unreported. METHODS: Consecutive patients who underwent transfemoral TAVR with the Lotus Valve system were analyzed. AA was determined on pre-procedural multi-detector computed tomography imaging. Device success, procedural characteristics, and clinical events were assessed according to Valve Academic Research Consortium-2 (VARC2) definitions. RESULTS: One hundred sixty-five patients were analyzed (48% male, mean age 84 years). The mean AA was 47.8 degrees. Patients were, therefore, divided into low AA (AA < 48°) or high AA (AA ≥ 48°). Baseline characteristics were similar in both cohorts. Device success and procedural outcomes were also similar including procedure time, contrast dose, and need to reposition. There was no difference in degree of moderate or greater para-valvular regurgitation (PVR) (0% vs. 3%, P = 0.09). Clinical outcomes of death, stroke, myocardial infarction, and other major VARC2 endpoints were similar. CONCLUSION: AA did not affect device success or clinical outcome with the Lotus Valve system. The Lotus' unique design features may have mitigated the impact of AA by improving the accuracy, ease of valve positioning, and reducing PVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...